919769350038 919769350038
Giri Trading

Secondary Injection Test Set

Secondary Injection Test Set

Product Details

Input 220 Volts ± 10 %, 50hz Ac Single Phase
Output Current 0-100 Amos
Current Range 0 -1- 5 - 10 - 25 - 50 & 100 Amps (Selectable & Continuously Variable)
Output AC Voltage Output AC Voltage 0-V Continuously Variable. 250
Output D.C. Voltage 270 V. Continuously Variable
Burden Continuous

Preferred Buyer From

Location Worldwide

The Giri Trading make Relay Test Set (PE-RTS) is a portable equipment, which is designed to check the operating characteristics of protective devices. Protective devices such as relays in the system are installed to deal with various fault conditions and its failure to operate correctly can cause serious damage to substations causing plant shutdown or power outgoes resulting in financial losses.

 

Application

To check all types of Electromagnetic relays like Over current, Earth Fault, Over voltage, Under Voltage and other relays to ensure smooth and fault free operations in plants and power substations.

 

Features

  • Single compact unit equipment suitable for field as well as workshop application.
  • Offer specified out put current selectable and continuously variable.
  • Digital Meter with LED display to measure output currents and voltages
  • Built in 1 no Digital Time interval meter having range from 0.0001 sec. to 9999 sec.
  • Auto cut off facility to cut off output on operation of device under test.
  • Housed in powder coated steel cabinet with all the control

 

Accessories

  • Instruction Manual.
  • Output connecting cables.
  • Mains cord.
  • Calibration report.
  • Warranty Card

 

Metering/ Display

  • 1 No digital AC Ammeter with LED display to measure output current.
  • 1 No. digital AC voltmeter with LED display to measure AC output voltage.
  • 1 No digital DC voltmeter with LED display to measure DC. output voltage.
  • 1 No Digital Time Interval Meter having Range from 0.0001 sec. to 99% sec with LED display. Protection and Safety AUTO
  • cut off Facility The set is provided facilities to cut off the output when the Relay under test is tripped Fuse protection provided for overload protections.

Yes! I am interested

Submit Your Requirement


Table No. 1 Rating oF Standard Models

Model Name Output current rating in AMPS Burden Capacity in KVA
GT-RTS 100 100 A 600 VA (MAX)
GT-RTS 50 50 A 600 VA (MAX)
GT-RTS 25 25 A(3 Phase) 600 VA (MAX)

 

Note we carry out customization as per customer Requirements 


  • Explore More Products




Looking for "Secondary Injection Test Set" ?